Explosionproof, Dust-Ignitionproof. 50 W, 70 W, 100 W, 150 W, 250 W, 400 W HPS; 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH - CSA*. Integrally Ballasted. Mogul Base. For Use with Threaded Metal Conduit.
- NEC:
- Class I, Division 1 and 2, Groups C, D
- Class II, Division 1 and 2, Groups E, F, G
- Class III
- Marine Type Electric Fixtures
- Outside Type (Saltwater)
- CEC: - CSA*
- Class I, Division 1 and 2, Groups B, C, D
- Class I, Zone 1 and 2; IIB, IIA
- Class II, Division 1, Groups E, F, G
- Class II, Division 2, Groups F, G
- Class II
- CSA Type 4X
- Exd IIB, Zone 1
These factory sealed, integrally ballasted HID luminaires are available in a wide range of lamps and wattages, and are suitable for use in hazardous locations as well as areas exposed to corrosive atmospheres, moisture or salt water.
Code•Master 2™ HID Factory Sealed Luminaires Catalog Pages
- Ideal for use in chemical and petrochemical plants, such as manufacturers of plastics, paints and thinners; in refineries; and in other process areas where ignitable vapors, dust, moisture and corrosive elements may be present
- Suitable for use in wet locations
- Copperfree aluminum construction with epoxy powder coat finish, fiberglass reinforced polyester reflectors, porcelain socket with nickel-plated phosphor bronze screw shell
- Choice of light sources: high pressure sodium, pulse start metal halide or metal halide
- A wide range of ballasts and voltages are available for both domestic and export applications
- Choice of mountings: pendant, ceiling, bracket and stanchion
- Fiberglass-reinforced polyester reflectors in standard dome, deep dome or 30° angle provide superior resistance to severely corrosive atmospheres
- Optional high bay aluminum reflector recommended for mounting heights of 20 feet/6 meters and higher from work plane
- Fixtures operate safely and with long life in high ambient temperatures
- Arrangement of heat producing components results in efficient heat dissipation for cooler fixture operation
- “Wireless” design: threading fixture unit onto mounting hood makes electrical connection (the only wiring required is attaching two wires to connection block in mounting hood)
- Safe, easy servicing or replacement without disconnecting any wiring
- Acme double-lead threads do not stick or gall, and require only half as many turns as single-lead threads when installing or removing fixture from mounting hood
- All threaded joints are flame-tight
- Integrally ballasted – separate ballasts not required
- Factory sealed – external seals not required
- Position of the lamp socket and interior prism design of the glass globe provide optimum light distribution and control
- Heat and impact-resistant globes have smooth, dust-resistant exterior
- Superior corrosion resistance
- Shock-absorbing medium base socket mounts prolong lamp life
- Optional guards attach with stainless steel screws to protect globe from damage
- Ballasts operate at low temperatures – PSMH: -29°C/-20°F; HPS: -40°C/-40°F; MH: -35°C/-31˚F
- 50 W through 150 W HPS ballasts are high reactance, high power factor type
| CAC-100 |
CLC2575 |
CPB1775TTCN |
| CAC-75 |
CLC2575TTCN |
CPB2510 |
| CALB-100 |
CLC4010 |
CPB2510TTCN |
| CALB-75 |
CLC4010TTCN |
CPB2575 |
| CAP-100 |
CLC4075 |
CPB2575TTCN |
| CAP-75 |
CLC4075TTCN |
CPB3210 |
| CAS-150 |
CLC5010 |
CPB3210TTCN |
| CF-10 |
CLC5075 |
CPB3275 |
| CF-2 |
CLC7010 |
CPB3275TTCN |
| CF-3 |
CLC7010TTCN |
CPB3510 |
| CF-5 |
CLC7075 |
CPB3510TTCN |
| CGL-250 |
CLC7075TTCN |
CPB3575 |
| CGL-400 |
CLP1010 |
CPB3575TTCN |
| CGU2 |
CLP1010TTCN |
CPB4010 |
| CGU4 |
CLP1075 |
CPB4010TTCN |
| CHB1710TTCN |
CLP1075TTCN |
CPB4075 |
| CHB1775TTCN |
CLP1510 |
CPB4075TTCN |
| CHB2510TTCN |
CLP1510TTCN |
CPC1710 |
| CHB2575TTCN |
CLP1575 |
CPC1710TTCN |
| CHB4010TTCN |
CLP1575TTCN |
CPC1775 |
| CHB4075TTCN |
CLP2510 |
CPC1775TTCN |
| CHC1710TTCN |
CLP2510TTCN |
CPC2510 |
| CHC1775TTCN |
CLP2575 |
CPC2510TTCN |
| CHC2510TTCN |
CLP2575TTCN |
CPC2575 |
| CHC2575TTCN |
CLP4010 |
CPC2575TTCN |
| CHC4010TTCN |
CLP4010TTCN |
CPC3210 |
| CHC4075TTCN |
CLP4075 |
CPC3210TTCN |
| CHP1710TTCN |
CLP4075TTCN |
CPC3275 |
| CHP1775TTCN |
CLP5010 |
CPC3275TTCN |
| CHP2510TTCN |
CLP5075 |
CPC3510 |
| CHP2575TTCN |
CLP7010 |
CPC3510TTCN |
| CHP4010TTCN |
CLP7010TTCN |
CPC3575 |
| CHP4075TTCN |
CLP7075 |
CPC3575TTCN |
| CHS17150TTCN |
CLP7075TTCN |
CPC4010 |
| CHS25150TTCN |
CLS10150 |
CPC4010TTCN |
| CHS40150TTCN |
CLS10150TTCN |
CPC4075 |
| CLB1010 |
CLS15150 |
CPC4075TTCN |
| CLB1010TTCN |
CLS15150TTCN |
CPP1710 |
| CLB1075 |
CLS25150 |
CPP1710TTCN |
| CLB1075TTCN |
CLS25150TTCN |
CPP1775 |
| CLB1510 |
CLS40150 |
CPP1775TTCN |
| CLB1510TTCN |
CLS40150TTCN |
CPP2510 |
| CLB1575 |
CLS50150 |
CPP2510TTCN |
| CLB1575TTCN |
CLS70150 |
CPP2575 |
| CLB2510 |
CLS70150TTCN |
CPP2575TTCN |
| CLB2510TTCN |
CMAD-1 |
CPP3210 |
| CLB2575 |
CMBH175 |
CPP3210TTCN |
| CLB2575TTCN |
CMBH250 |
CPP3275 |
| CLB4010 |
CMBH400 |
CPP3275TTCN |
| CLB4010TTCN |
CMBL100 |
CPP3510 |
| CLB4075 |
CMBL150 |
CPP3510TTCN |
| CLB4075TTCN |
CMBL250 |
CPP3575 |
| CLB5010 |
CMBL400 |
CPP3575TTCN |
| CLB5075 |
CMBL50 |
CPP4010 |
| CLB7010 |
CMBL70 |
CPP4010TTCN |
| CLB7010TTCN |
CMBP175 |
CPP4075 |
| CLB7075 |
CMBP250 |
CPP4075TTCN |
| CLB7075TTCN |
CMBP320 |
CPS17150 |
| CLC1010 |
CMBP350 |
CPS17150TTCN |
| CLC1010TTCN |
CMBP400 |
CPS25150 |
| CLC1075 |
CMR-4AN |
CPS25150TTCN |
| CLC1075TTCN |
CMR-4DD |
CPS32150 |
| CLC1510 |
CMR-4HB |
CPS32150TTCN |
| CLC1510TTCN |
CMR-4ST |
CPS35150 |
| CLC1575 |
CMS-400 |
CPS35150TTCN |
| CLC1575TTCN |
CPB1710 |
CPS40150 |
| CLC2510 |
CPB1710TTCN |
CPS40150TTCN |
| CLC2510TTCN |
CPB1775 |
VPT-7 | |
|
|
* CSA Certification only.
|


EGS Petrochem Brochure
|