|
|
Factory Sealed. 10 to 100 Amps. Explosionproof, Dust-Ignitionproof, Watertight, Corrosion Resistant.
- Class I, Division 1 and 2, Groups B *, C *, D
- Class II, Division 1 and 2, Groups E, F, G
- Class III
- NEMA 3, 3R, 4, 4X, 7BCD, 9EFG, 12
D2P and EWP factory sealed circuit breaker panelboards provide protection and control of electrical equipment and circuits in hazardous locations or in damp, wet or corrosive conditions. While the D2P Series is suitable for many of the most common hazardous areas, the EWP Series provides the extra protection needed for Class I, Division 1 areas.
D2P and EWP Factory Sealed Circuit Breaker Panelboards Catalog Pages
- Control and protection of electrical equipment in wet, corrosive and hazardous environments
- Control and protection of lighting, heat tracing and other circuits
- The D2P Series is designed for use in Class I, Division 2 areas where ignitable vapors or gases may be present under unusual conditions, or in Class II, Division 1 areas where combustible dusts are present
- The EWP Series is designed for use in Class I and II, Division 1 areas where ignitable vapors, gases or combustible dusts are present
- Group B protection is standard on all D2P and EWP panelboards, provided that all conduits are sealed adjacent to the enclosure
- Copperfree aluminum housings with epoxy powder coat, stainless steel hardware
- Factory sealed — no external branch sealing fittings needed (except Division 1 Groups B and C)
- Three sizes available for up to 12, 24 or 36 single-pole spaces
- Permits selection of 1-, 2- or 3-pole breakers. Types EPD, GFI and HID available as options
- 10,000 Amp Vac interrupting capacity (22,000 AIC optionally available)
- Voltage ratings: 120 Vac for 1-pole, up to 240 Vac for 2- or 3-pole
- Uses standard Quicklag circuit breakers
- Aluminum breaker actuators are spring loaded, corrosion resistant, and feature a self-locating design for actuating breakers in any sequence
- Actuating handles can be individually padlocked in On or Off position without interfering with tripping of breakers
- 3" main conduit openings for both top and bottom feed of junction compartment
- Doors for junction and breaker compartments are both fully gasketed for a raintight fit
- Doors can be lifted off hinges for easy service
- Provision for drains/breathers in both compartments
- Double O-ring gaskets on each breaker handle prevent entrance of water or corrosion
- Breakers are prewired to terminal blocks to minimize installation time
- Insulated neutral lug
- Stainless steel captive spring-out bolts for ease of access
- Wide range of panel options available
| D2P4A10 |
D2P5B16 |
EWP4C26 |
| D2P4A12 |
D2P5B18 |
EWP4C28 |
| D2P4A6 |
D2P5B20 |
EWP4C30 |
| D2P4A8 |
D2P5B22 |
EWP4C32 |
| D2P4B14 |
D2P5B24 |
EWP4C34 |
| D2P4B16 |
D2P5C26 |
EWP4C36 |
| D2P4B18 |
D2P5C28 |
EWP5A10 |
| D2P4B20 |
D2P5C30 |
EWP5A12 |
| D2P4B22 |
D2P5C32 |
EWP5A6 |
| D2P4B24 |
D2P5C34 |
EWP5A8 |
| D2P4C26 |
D2P5C36 |
EWP5B14 |
| D2P4C28 |
EWP4A10 |
EWP5B16 |
| D2P4C30 |
EWP4A12 |
EWP5B18 |
| D2P4C32 |
EWP4A6 |
EWP5B20 |
| D2P4C34 |
EWP4A8 |
EWP5B22 |
| D2P4C36 |
EWP4B14 |
EWP5B24 |
| D2P5A10 |
EWP4B16 |
EWP5C26 |
| D2P5A12 |
EWP4B18 |
EWP5C28 |
| D2P5A6 |
EWP4B20 |
EWP5C30 |
| D2P5A8 |
EWP4B22 |
EWP5C32 |
| D2P5B14 |
EWP4B24 |
EWP5C34 |
|
|
EWP5C36 | |
|
|
* For Groups B and C, all conduits must be sealed adjacent to enclosure.
|


Appleton Panelboards Brochure

Appleton Enclosures and Controls Quick Response Program Brochure
|