Code•Master 2 HID Floodlight

Marine (Outside Type). Explosionproof.
150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH;
150 W, 250 W, 400 W HPS; 175 W, 250 W, 400 W MH*.
Integrally Ballasted. Mogul Base.

  • NEC:
    – Class 1, Division 1 and 2, Groups C, D
    Marine Type Electric Fixtures
    Outside Type (Saltwater)
  • CEC*
    Class I, Division 1 and 2, Groups B, C, D
    Class II, Division 1, Groups E, F, G
    Class II, Division 2, Groups F, G
    Class III
    CSA 4X 

Listed for marine use, these factory sealed HID floodlights are suitable for use in Class I, Division 1 hazardous locations encountered in oil and gas production and transportation. 

Code•Master 2 HID Floodlights Catalog Pages 

Applications Features Catalog Numbers
  • UL Listed for Marine Type Electric Fixtures Outside Type (Salt Water).
  • Ideal in Class I, Division 1 and 2 installations in refi neries, in pipeline transportation facilities, at drilling rigs and in production facilities on land and marine platforms.
  • Class I, Division 1 areas include:
  1. (1) enclosed derricks, mud tanks, desander-desilter, gasoperated control devices, oil-gas separation vessels, shale shakers and flowing or beam wells
  2. (2) flowing or beam wells in open areas with cellar or below grade sump
  3. (3) on refinery docks where tankers are loaded with hoses or loading arms
  4. (4) in compressor buildings (open or enclosed) where methane gas is present
  • Virtually all enclosed areas at drilling operations or refineries where ventilation is inadequate, or where a cellar or below grade sump exists, are Class I, Division 1.

​* CSA Certification only.

Appleton