NEC, CEC Explosionproof

NEC and CEC Explosionproof, Dust-Ignitionproof Sealing Fittings.
 

Appleton Group manufactures sealing fittings certified for use in Class I, Division 1 and 2 locations to comply with NEC and CEC requirements. They are used to prevent the passage of gases, vapors or flames from one portion of conduit system to another, restrict any explosion to the sealed off enclosure and to prevent pressure piling within conduit system. 

Appleton’s ALESKO epoxy sealing putty is CSA Approved to prevent the passage of gases, vapors or flames from one portion of a conduit system to another by restricting any explosion within the sealed off enclosure.
Appleton ES 25% fill sealing hubs are used to seal vertical conduit risers at switch gear and motor control centers, sheet metal structures, or cast boxes and enclosures.
Appleton’s ESU Series prevents pressure building within the conduit system and contains any explosion that occurs. They provide a pouring spout that rotates 90° for sealing vertical or horizontal conduit.
Appleton hazardous location EY 25 percent fill vertical or horizontal sealing fittings contain any explosion that occurs by minimizing the passage of gases and vapors and preventing the passage of flames from one portion of a conduit system to another.
Appleton hazardous location EY 40 percent fill vertical or horizontal sealing fittings contain any explosion that occurs by minimizing the passage of gases and vapors and preventing the passage of flames from one portion of a conduit system to another.
O-Z/Gedney EY and EYM 25 percent fill vertical conduit sealing fittings minimize the passage of gases and vapors and prevent the passage of flames from one portion of an electrical system to another through the conduit.
O-Z/Gedney EYA and EYAM 25 percent fill vertical or horizontal conduit sealing fittings minimize the passage of gases and vapors and prevent the passage of flames from one portion of an electrical system to another through the conduit.
O-Z/Gedney EYAX vertical, horizontal 40 percent expanded fill sealing fittings minimize the passage of gases and vapors and prevent the passage of flames from one portion of an electrical system to another through the conduit.
O-Z/Gedney EYD and EYDM 25 percent fill vertical drain, sealing fittings minimize the passage of gases and vapors from one portion of the electrical system to another through the conduit while preventing the passage of flames.
Appleton hazardous location EYD and EYDM 25 percent fill vertical conduit drain sealing fittings minimizes the passage of gases and vapors and prevents the passage of flames from one portion of a conduit system to another.
Appleton's EYS 25 percent fill vertical and horizontal conduit sealing fittings minimize the passage of gases and vapors and prevent the passage of flames from one portion of a conduit system to another and contain any explosion that occurs.
Appleton's EYS 25 percent fill vertical conduit sealing fittings for close turning radius minimize the passage of gases and vapors and prevent the passage of flames from one portion of a conduit system to another and contain any explosion that occurs.
Appleton hazardous location EYSF and EYSM 25 percent fill vertical sealing fittings minimize the passage of gases and vapors and prevent the passage of flames from one portion of a conduit system to another and contain any explosion that occurs.
Kwiko A sealing cement and filler contains and restricts the passage of gases and explosions in classified areas, fiber filler makes dams around and between conductors to prevent sealing compound from leaking while in its liquid state.
Appleton